Arsenic speciation analysis of human urine using ion exchange chromatography coupled to inductively coupled plasma mass spectrometry [An article from: Analytica Chimica Acta]
Arsenic speciation analysis of human urine using ion exchange chromatography coupled to inductively coupled plasma mass spectrometry [An article from: Analytica Chimica Acta]
Last Updated on Saturday, 10 September 2011 12:30 Written by Administrator Saturday, 10 September 2011 12:30
Arsenic speciation analysis of human urine using ion exchange chromatography coupled to inductively coupled plasma mass spectrometry [An article from: Analytica Chimica Acta]
This digital document is a journal article from Analytica Chimica Acta, published by Elsevier in 2006. The article is delivered in HTML format and is available in your Amazon.com Media Library immediately after purchase. You can view it with any web browser.
Description:
A sensitive and robust method for the determination of seven inorganic and organic arsenic species was developed using ion exchange chromatography combined with inductively coupled plasma mass spectrometry (IC-ICP-MS). Both anion and cation exchange columns were used in a complementary fashion. Arsenite (As(III)), arsenate (As(V)), monomethylarsonic acid (MMA(V)) and dimethylarsinic acid (DMA(V)) were selectively separated by an anion exchange column using sodium hydroxide (NaOH) gradient elution, while monomethylarsonous acid (MMA(III)), dimethylarsinous acid (DMA(III)) and arsenobetaine (AsB) were separated by a cation exchange column using 70mM nitric acid as the mobile phase. Baseline separation, high repeatability and low detection limits (0.10-0.75ngmL^-^1) were achieved. The spiked urine samples were analyzed with this method to evaluate the matrix effect on the method. The results suggest 1-10 dilutions should be made to urine samples before sample injection for the anion exchange analysis to minimize the matrix effect. To validate the method, a new standard reference material (NIST SRM-2670a) was also analyzed. The arsenic species in NIST SRM-2670a were determined by this method, and the sum of their concentrations agreed well with the total arsenic content certified for NIST SRM-2670a. Moreover, this method was applied to measure arsenic species in urine samples from one subject living in New Jersey who drank well water contaminated with arsenic. By this method, two key arsenic metabolites, MMA(III) and DMA(III), were found to be present in these urine samples, which has previously been rarely reported.
List Price: $ 10.95
Price: $ 10.95
Related Mass Spectrometry Articles
- Analysis of size characterized manganese species from liver extracts using capillary zone electrophoresis coupled to inductively coupled plasma mass spectrometry … [An article from: Analytica Chimica Acta]
Analysis of size cha... - Arsenic speciation in Chinese brake fern by ion-pair high-performance liquid chromatography-inductively coupled plasma mass spectroscopy [An article from: Analytica Chimica Acta]
Arsenic speciation i... - Determination of itopride in human plasma by liquid chromatography coupled to tandem mass spectrometric detection: Application to a bioequivalence study [An article from: Analytica Chimica Acta]
Determination of ito... - Simultaneous quantification of 17 trace elements in blood by dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS) equipped with … [An article from: Analytica Chimica Acta]
Simultaneous quantif... - Determination of 36 elements in plant reference materials with different Si contents by inductively coupled plasma mass spectrometry: Comparison of microwave … [An article from: Analytica Chimica Acta]
Determination of 36 ...
Related Mass Spectrometry Articles
- Analysis of size characterized manganese species from liver extracts using capillary zone electrophoresis coupled to inductively coupled plasma mass spectrometry … [An article from: Analytica Chimica Acta]
Analysis of size cha... - Arsenic speciation in Chinese brake fern by ion-pair high-performance liquid chromatography-inductively coupled plasma mass spectroscopy [An article from: Analytica Chimica Acta]
Arsenic speciation i... - Determination of itopride in human plasma by liquid chromatography coupled to tandem mass spectrometric detection: Application to a bioequivalence study [An article from: Analytica Chimica Acta]
Determination of ito... - Simultaneous quantification of 17 trace elements in blood by dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS) equipped with … [An article from: Analytica Chimica Acta]
Simultaneous quantif... - Determination of 36 elements in plant reference materials with different Si contents by inductively coupled plasma mass spectrometry: Comparison of microwave … [An article from: Analytica Chimica Acta]
Determination of 36 ...
Tags: Acta, Analysis, Analytica, Arsenic, article, Chimica, CHROMATOGRAPHY, Coupled, exchange, From, human, Inductively, Mass, Plasma, speciation, Spectrometry, urine, Using

